STK14CA8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AutoStore/POWER UP RECALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO.

Symbols

Parameter

STK14CA8

Units

Notes

 

 

Standard

Alternate

Min

Max

 

 

 

 

 

 

 

 

22

tHRECALL

 

 

 

Power up RECALL Duration

 

20

ms

9

 

 

23

tSTORE

tHLHZ

STORE Cycle Duration

 

12.5

ms

10, 11

 

 

24

VSWITCH

 

 

 

Low Voltage Trigger Level

 

2.65

V

 

 

 

25

VCCRISE

 

 

 

VCC Rise Time

150

 

μs

 

 

 

t

Figure 10. AutoStore/POWER UP RECALL

25

23

23

22

22

Note Read and Write cycles are ignored during STORE, RECALL, and while VCC is below VSWITCH.

Notes

9.tHRECALL starts from the time VCC rises above VSWITCH

10.If an SRAM WRITE has not taken place since the last nonvolatile cycle, no STORE takes place

11.Industrial Grade devices require maximum 15 ms.

Document Number: 001-51592 Rev. **