Adding or Replacing a DC PEM

Connecting DC Power

Warning Only a DC power source that is isolated from AC mains with reinforced insulation, and that complies with the other safety extra-low voltage (SELV) requirements in UL1950, CSA 950 3rd Edition, EN 60950, and IEC950, can be connected to a Cisco 10005 system. This requirement ensures that in a catastrophic power source fault condition, hazardous voltages are not present on power terminals and connectors.

Follow these steps to connect DC power to the Cisco 10005 ESR. Refer to

Figure 7.

Step 1 Ensure that power in the DC circuit is off.

Step 2 Ensure that the PEMs are fully inserted into the chassis and secured with their captive screws.

Step 3 Ensure that the circuit breaker on the newly installed PEM is set to 0 (Off).

Step 4 Turn the + and – screws on the new PEM’s terminal block counter-clockwise to fully open the terminal connectors. This step ensures that the correct opening is presented for the wires (see Figure 5).

Step 5 Insert the battery return wire from the external power source into the receptacle labeled + (positive) on the PEM (Figure 7). The stripped part of the wire must be fully inserted so that no bare wire is exposed. Use the screwdriver to tighten the terminal screw to a torque of 1.5 to 1.8 newton meters (13.28 to

15.93 inch-pounds). (Tighten the screws clockwise.)

Warning The illustration shows the DC power supply terminal block. Wire the DC power supply as illustrated. The proper wiring sequence is ground to ground, positive to positive, and negative to negative. The ground wire must always be connected first and disconnected last.

 

Cisco 10005 ESR DC Power Entry Module Installation

16

78-12653-01