Operation
Shipping Information
| U.S.A. | Metric |
|
|
|
Length | 111 in. | 282 cm |
|
|
|
Width | 42 in. | 107 cm |
|
|
|
Height | 82 in. | 208 cm |
|
|
|
Weight | 2470 lbs. | 1120 kg |
|
|
|
NOTE: Applicable codes, ordinances, specifications and/or other governing data related to installation must be complied with. The materials listed in Table 1 may or may not conform to these requirements.
Materials Required
Quantity | Description | Source |
|
|
|
1 | Lockout type fused disconnect switch suitable for the electric service connected to | Local |
| the press (refer to wiring schematic in control box) (not required if circuit breaker is |
|
| used) |
|
|
|
|
As required | Wire of suitable size, type and length to connect the electric service to the press | Local |
| (refer to wiring schematic in control box) |
|
|
|
|
As required | Flexible conduit and connections to encase the wires and make connections | Local |
| (refer to wiring schematic in control box) |
|
|
|
|
3 | Steam trap and check valve, or combination steam trap/check valve sized steam | Local |
| return lines and steam consumption |
|
|
|
|
3 | Ball | Local |
|
|
|
As required | Pipe, couplings, unions, flanges, etc., to connect steam supply and return lines and | Local |
| air supply line to press. Wall thickness of pipe and tubing must be in compliance |
|
| with recommendations by compressor and boiler manufacturers and local code. |
|
|
|
|
6 | 5/8 in. anchor bolts | Local |
|
|
|
As required | Machinery grout (if machine sits 1/2 in. [12.7 mm] or greater off of floor) | Local |
|
|
|
As required | Pipe, couplings, unions, flanges, etc., to route air bag blower exhaust away from the | Local |
| press |
|
|
|
|
| Table 1 |
|