Routing Blower Exhaust from Press
Blower exhaust can add unwanted heat and noise into a room. Route blower exhaust from press upward near ceiling or to outside. Running exhaust outside is recommended. If running exhaust outside, make sure rain cannot get in.
Install exhaust piping from exhaust muffler as follows:
1.Use coupling to connect minimum amount of
2.Run pipe to ceiling area or outside building. Support pipe as required. The end of the pipe run should be bell shaped and pointed downward to avoid collecting debris.
IMPORTANT: Pipe must be adequately supported. When using CPVC, support the pipe every 5 feet (1.52 m).
NOTE: Use 45 degree bends wherever possible. avoid 90 degree bends.
3.Exhaust can be routed into common header with other presses. Header must be suitably sized. Refer to Table 2.
NOTE: Bring pipe into header using Y tee. Angle pipe so air is routed toward opening to atmosphere.
IMPORTANT: Undersized header WILL shorten motor life and void warranty.
No. of Connections | Header Pipe Size |
|
|
2 | |
|
|
3 | 3 in. (7.62 cm) |
|
|
4 | |
|
|
5 | 4 in. (10.16 cm) |
|
|
6 | 5 in. (12.70 cm) |
|
|
Table 2
Operation
Final Check-Out Procedures
NOTE: Refer to Operation Manual to identify controls before performing the following check- outs.
Buck Indexing Mechanical Check-Out
The following steps outline the procedure for buck indexing mechanical
WARNING
To avoid possible serious injury:
•BEFORE attempting to pull buck out of cabinet,
ALWAYS shut off AND lock out ALL electric, air and steam power to press AND allow heated surfaces to cool
•ONLY USE ORANGE HANDLE to push and pull buck IN and OUT of CABINET.
W439
1.Pull buck out to dressing position.
2.Turn on air to press and reset air circuit. Pressure gauge should read line pressure 65 psi.
3.Step on the right foot pedal. Collar clamp should open. Release the foot pedal and collar clamp should close.
4.Step on the left foot pedal. Sleeve extender arms should swing outward away from buck.
5.Press the sleeve extender release button. Sleeve extenders should swing inward toward buck.
6.Simultaneously press and release both BUCK IN buttons. Buck should travel into pressing position inside the cabinet and heads close.
7.Check that the collar block is positioned in the head cutout per Figure 6. If collar block is not properly aligned, check press level. If press is level, shim buck, adjust collar block or discharge tube as necessary.
AJ0976 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 13 |