Operation

1/8 in. (3 mm)

1/8 in.

(3 mm)

1/8 in.

(3 mm)

CAB240N

Figure 6

8.Press the head release button. Heads should open and buck should return to the dressing station.

9.Simultaneously press and release both buck in buttons. As buck travels into cabinet, press red safety bar which is near the operator. Buck travel should stop, press heads should remain open and air should exhaust from the system. Pressure gauge should read 0 psi.

10.Reset air to press. Simultaneously press and release both buck in buttons. Allow buck to travel into cabinet and heads to close. Press other red safety bar. Press heads should open, buck should remain stationary and air should exhaust from the system. Pressure gauge should read 0 psi.

WARNING

To avoid possible serious injury, NEVER use press unless BOTH safety bars and BUCK IN BUTTONS are working properly.

W369

11.Reset air to press. Simultaneously press and release both buck in buttons. Allow buck to travel into cabinet and heads to close. Press emergency stop button. Press heads should open, buck should remain stationary and air should exhaust from the system. Pressure gauge should read

0 psi.

Electrical Check-Out

Black and red electrical control buttons start and stop all electrical functions.

1.Reset air to press per step 1 in Buck Indexing Mechanical Check-Out. Turn electrical on to press at fused disconnect switch or circuit breaker.

2.Make sure Emergency Stop button is up if applicable.

3.Press black start button.

NOTE: Start button will not start blower unless air is reset to press.

4.Check blower for proper rotation. Check airflow direction at press muffler. Air should be exhausting from muffler. If air is sucked in toward muffler, change any two wires in the electrical connection box.

5.Check isolation damper between sleeve heat exchanger and blower. Air cylinder should extend to open damper.

6.Step on left foot pedal. Vacuum should turn on to buck. Press vacuum release button. Vacuum should turn off to buck.

7.Set cycle timer selector switch to on position and set pressing cycle timer for approximately

35 seconds. Turn steam timer selector switch to off position. Send buck into pressing position. Heads should close and remain closed for approximately 35 seconds.

8.When press heads open, the buck should automatically return to the dressing position.

9.Turn steam timer selector switch to the on position. Set steam timer for 5 seconds. Send buck into pressing position. Blower air should blow through arm holes after a 5 second delay and remain on until cycle timer times out.

10.After all checks (steps 1 through 9) are completed, proceed with Steam Injection and Temperature Check-Out.

14