Printer Operation

Mode Settings

Menu Setting Table

Page Setup Menu - allows you to change settings related to the media or print quality.

System Setup Menu - allows you to change settings for the printer hardware and basic control systems. After Print Menu - changes how the printer reacts after the label has been printed.

Interfaces - changes interface parameters such as baud rate.

Machine Information, Test Mode - allows you to check and/or print test pages and information about the printer. Global Config menu - allows you to switch between 3 complete ‘config sets’ contained within the printer.

Menu Setting

Press the MENU key in print possible status to enter MENU Setup Mode. Use the keys on the operation panel according to the LCD display to setup the printer. The contents that can be setup on the printer are shown below. And the items that are actually displayed on the LCD are shown in [ ].

Top Menu

Sub Menu

Default

Menu

Remarks

Page Setup

Print Speed

7 IPS

2 to 10 IPS

Printing speed setting.

 

 

 

 

 

 

Print Darkness

12

00 to 30

Adjusting print darkness.

 

 

 

 

 

 

Darkness Adjust

00

-10 to 10

Fine adjustment of darkness commands.

 

[Darkness Adj]

 

 

 

 

 

 

 

 

Print Method

TT

TT (Thermal Transfer) Selection of Thermal Transfer (ribbon) or

 

 

 

DT (Direct Thermal)

Direct Thermal.

 

 

 

 

 

 

Continuous Media

4.00 inch

0.25 to 32.00 inch

Setting media length of continuous media.

 

Length

101.6 mm

6.4 to 812.8 mm

Lower level = during mm mode.

 

[Cont Media Len]

 

 

 

 

 

 

 

 

 

Vertical Position

0.00 inch

-1.00 to 1.00 inch

Adjusting printing start position.

 

[Vertical Pos]

0.0 mm

-25.4 to 25.4mm

 

 

 

 

 

 

 

Horizontal Position

0.00 inch

-1.00 to 1.00 inch

Adjusting horizontal image position.

 

[Horizontal Pos]

0.0 mm

-25.4 to 25.4mm

 

 

 

 

 

 

 

Sensor Select

Rear Adj Sensor

Rear Adj Sensor

Selecting front fixed/rear adj. sensor.

 

 

 

Front Fixed Sen

 

 

 

 

 

 

 

Media Sensor

See Through

See Through

Selecting media sensor.

 

 

 

Reflect

 

 

 

 

None

 

 

 

 

 

 

 

Small Media

Off

On

Setting for small media.

 

Adjustment

 

Off

 

 

[Small Media Adj]

 

 

 

 

 

 

 

 

 

Small Media

1.00 inch

0.25 to 1.00 inch

Setting media length for small media.

 

Length

25.4 mm

6.4 to 25.4mm

 

 

[Small Media Len]

 

 

 

 

 

 

 

 

 

Symbol Set

PM

50 symbols

Setting symbol set.

 

 

 

 

 

System Setup

Sensor Monitor

Displays level of sensor that is currently

 

 

 

 

selected.

 

 

 

 

 

 

Sensor Level

1.4 V

0.0 V to 3.0 V

Selects threshold of the sensor.

 

 

 

 

 

 

Paper End Level

2.80 V

0.01 V to 3.00 V

Sets the paper end level.

 

 

 

 

 

 

Cover Open Sensor

Off

On

Sets the cover open sensor.

 

[Cover Sensor]

 

Off

 

 

 

 

 

 

 

MENU/REPEAT

MENU Key

MENU Key

Sets the MENU key.

 

Select

 

REPEAT Key

 

 

[MENU/REPEAT Sel]

 

 

 

 

 

 

 

 

 

Buzzer Select

Exec/Err

Exec/Err

Setting buzzer sounding conditions.

 

 

 

All

 

 

 

 

Error

 

 

 

 

Key

 

 

 

 

None

 

 

 

 

 

 

37