[Function]

Sets Memory Switch

 

 

 

 

 

 

 

 

[Code]

ASCII

<ESC>"#N, n1

n2

n3

n4" <LF> <NUL>

 

Hexadecimal

1B 23

N

2C n1

n2

n3

n4

0A

00

 

Decimal

27 35

N

44

n1

n2

n3

n4

10

0

N: Memory switch segment number (4 and 5 only) n1 n2 n3 n4: Set data

[Range]

N="4"(34h) or "5"(35h)

 

"0"(30h)n1,n2,n3,n4"9"(39h) or "A"(41h)n1,n2,n3,n4"F"(46h)

[Outline]

The memory switch is stored in the nonvolatile EEPROM memory. To change this setting, send

 

a command from the host side. After setting with the command, turn on the power again, or

 

reset with the following reset command, to enable setting. (If reset with the command, self-

 

printing will be implemented.)

 

Reset command: <ESC> <CAN> <LF> <NUL>

[Caution]

The EEROM has a data-writing life. Do not execute this command every time. Note that if the

 

EEROM’s life is running out due to frequent use of this command, printer operation cannot be

 

guaranteed.

 

The memory switch segment numbers other than 3 to 5 do not have relevant setting items, but

 

they actually exist. Therefore, use of other numbers besides 3 to 5 will be valid as a command

 

and change the data in the EEROM. If this is the case, operation will not be guaranteed.

 

Exercise full care when using this command.

1)Memory Switch 4 (MSW4)

The setting upon shipment from the factory is indicated with “ * ”.

 

 

Bit

 

Description

0

1

 

 

 

 

 

 

 

 

 

F

 

 

 

 

n1

 

E

 

 

 

 

 

 

D

 

 

 

 

(LSB)

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

B

 

 

 

 

n2

 

A

 

 

 

 

 

 

9

 

 

 

 

(LSB)

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

n3

 

6

 

 

Checks *

 

 

 

5

 

DSR signal check at status sending time

Does not check

(LSB)

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

n4

 

2

 

 

 

 

 

 

1

 

 

Prints "?" *

 

(LSB)

 

0

 

Data reception

Ignores

(

 

: Denotes setting enabled)

 

 

(Note) X-ON/X-OFF output timing: Setting whether to output the X-ON code every 3 seconds

– 44 –