6.SERIAL INTERFACE

6.1Specifications

(1)Synchronization: Asynchronous

(2)Baud rate

1200, 2400, 4800, 9600, 19200 Baud/sec (User selection)

(3)Word configuration

•Start bit: 1 bit

•Data bit: 7 bits or 8 bits (User selection)

•Parity bit: odd, even, no parity (User selection)

•Stop bit: 1 bit or more

(4)Signal polarity RS-232C

•Mark = Logic “1” (−3 V to −12V)

•Space = Logic “0” (+3 V to +12 V)

Selecting presence or absence of signal is available with TTL (RESET) DIP switch No. 3.

•H level = Logic “1”

•L level = Logic “0”

(5)Receive data (RD)

•Mark: “1”

•Space: “0”

(6)Transmit data (TD)

•Mark: “1”

•Space: “0”

(7)Received control data (DTR) (DTR signal)

•Mark: Data transmission not possible

•Space: Data transmission possible

— 26 —