Citizen Systems CMP-10 manual Function, Auto Power OFF, Interface Selection, Low Battery Detection

Models: CMP-10

1 40
Download 40 pages 54.86 Kb
Page 31
Image 31
5.FUNCTION

5.FUNCTION

5.1Auto Power OFF

Power is automatically cut off after a specified period of time, during which no command is sent to the printer and the LF switch has not been pressed.

The default setting of this time duration is 10 minutes, however, the period can be custom set by the user with a special command to the printer. (see Command Reference List)

The behavior of the printer at the operation of Auto Power OFF is the same as that when power is turned OFF by the Power switch.

5.2 Interface Selection

The interface is automatically selected depending on the presence or absence of connection to the serial port with a serial cable connector.

At POWER ON, no cable is connected, the IrDA interface is selected.

At POWER ON, the cable is connected, the Serial interface is selected.

5.1Auto Power OFFCAUTION!

If cable is connected with printer power ON, selecting IrDA interface remains valid. If you want to use the serial interface, turn the printer power OFF once, connect the serial cable, and then turn the printer power ON again.

5.3 Low Battery Detection

Battery charge level is monitored at Power ON, before paper feeding, and before printing.

When the buzzer sounds three times or “Low Battery” is printed, immediately charge the battery.

— 27 —

Page 31
Image 31
Citizen Systems CMP-10 manual Function, Auto Power OFF, Interface Selection, Low Battery Detection