Step 1 : Press [ DATA ] 10

DEGSTAT

1 0.

Step 2 : The calculator updates the statistics as you enter data. You can recall all variable statistics to get the following result : x = 6.56, n = 9.00, S = 2.74, Σx = 59.00, Σx2 = 447.00, σ= 2.59, where data 1 = 2.00, data 2~5 = 5.00, data 6~8 = 9.00, data 9 = 10.00

Editing statistics data

(Ex.4) : Based on Ex.1, correct data 1 = 2 as data 1 = 3 Method 1 :

Press 2 [ 2ndF ] [ DEL ] 3 [=] to overwrite. Method 2 :

Step 1

: Press [ 2ndF ] [ EDIT ]

 

DEG

ED

 

STAT

 

 

 

0. 0

0

 

 

 

 

 

 

 

Step 2

: Find out 2 by [ DATA ] or [ = ]

 

DEG

ED

 

STAT

 

 

 

2. 0

0

 

 

 

 

 

 

 

Step 3

: Enter 3 to overwrite 2

 

DEG

ED

 

STAT

 

 

 

 

 

3.

 

 

 

 

 

 

 

 

 

Step 4 : Press [ = ] and [ 2ndF ] [ EDIT ] to exit ED mode,where those data are changed as data 1 = 3.00, data 2~5 = 5.00, data 6~8 = 9.00.

(Ex.5) : Based on Ex.1, delete data 1 = 2 . Method 1 :

Press 2 [ 2ndF ] [ DEL ] to delete 2. Method 2 :

Step 1

: Press [ 2ndF ] [ EDIT ]

 

DEG

ED

 

STAT

 

 

 

0. 0

0

 

 

 

 

 

 

 

Step 2

: Find out 2 by [ DATA ] or [ = ]

 

DEG

ED

 

STAT

 

 

 

2. 0

0

 

 

 

 

 

 

 

Step 3

: Press [ 2ndF ] [ DEL ]

 

DEG

ED

 

STAT

 

 

 

5. 0

0

 

 

 

 

 

 

 

Step 4 : Press [ 2ndF ] [ EDIT ] to exit ED mode, where those data are changed as data 1~4 = 5.00, data 5~7 = 9.00.

Delete error

(Ex.6) : If you enter and delete a value that isn’t included in the stored data by mistake, “dEL Error“ appears, but the previous data are still retained, for example, delete 7 based on Ex.1.

Step 1 : Press 7 [ 2ndF ] [ DEL ]

Step 2 : Press any key to clear it

DEGSTAT

dEL Error

DEGSTAT

0. 0 0

E18

SR-260N_English_090324.rtf

SIZE: 135x75mm

/ SCALE 2:1 / 2009/3/24

Page 19
Image 19