Clarke Propane Floor Burnisher MaintenanceofEquipment COSafetyEquipmentAvailable

Models: Propane Floor Burnisher

1 68
Download 68 pages 49.51 Kb
Page 10
Image 10

ENGLISH EN

8 Hour Time Weighted Average (OSHA Method)

1.5 % 750,000cf

Hours Operation

1

2

3

4

5

6

7

8

TWA (OSHA Method)

0 change/hr

5

14

27

46

69

96

128

164

 

1/2 change/hr

4

9

16

24

33

42

50

59

 

1 change/hr

3

7

11

16

20

25

29

34

 

2 change/hr

2

4

7

9

11

13

16

18

Based on the CO production rates shown above the TWAwould not be exceeded in a

100 x 750 x 10 foot (empty) space after 8 hours with 2 air changes per hour. (Assumes no additional CO exposure during 8 hour time period)

MaintenanceofEquipment

Warning: The proper maintenance of equipment is vital to safe operation. LPG engines are dependent on engine tune up, and air filter replacement. CO concentration (production) skyrockets when the air to fuel ratio becomes fuel rich. Follow the recommended Maintenance Schedule for the engine found in the Engine Operator/Owner Manual as well as the Maintenance And Adjustments schedule found in the Propane Floor Equipment Operator’s Manual that were supplied with the equipment. Additional manuals may be obtained by contacting Clarke at 1-800-545-3454 or write to Clarke Customer Service, 2100 Hwy. 265, Springdale AR 72764.

COSafetyEquipmentAvailable

Envirogard automated fuel to air ratio monitoring and regulation providing an optimum combustion

Three-way type catalytic converter to scrub CO, Hydro Carbons (HC), and Nitrous Oxide (NOx) from the engine exhaust providing the lowest possible emissions

High cubic feet per minute (CFM) fans (forced air mixing)

Digital combustion analyzers for tail pipe emissions monitoring

Page -10-

Clarke® Operator's Manual (EN) - DC Propane Burnisher

Page 10
Image 10
Clarke Propane Floor Burnisher manuel dutilisation MaintenanceofEquipment COSafetyEquipmentAvailable