Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
SFTYMUTE - Safety mute
Selects/reports the state of the safety mute. When on, the safety mute holds all
outputs on the selected unit in a muted state. It is used primarily for troubleshooting
G-Ware.
Command form: DEVICE
SFTYMUTE
[Value]
Argument details
Name Description
Device 0–7 or * to select all units
SFTYMUTE Command
Value 0 = Off, 1 = On, 2 = Toggle, Null = Current state
Example:
#52 SFTYMUTE 1
On XAP 800 unit 2 (
#52
), safety mute
(
SFTYMUTE
) is enabled (
1
).
SIGGEN - Signal Generator
This command selects/reports of the signal generator activation.
Command form: DEVICE
SIGGEN
<Channel> <Group> [Type] [Amplitude]
[Frequency]
Argument details
Name Description
Device 0–7 or * to select all units
SIGGEN Command
Channel See Groups and Channels, page 97
Group I, M, L
Type 0 = Off, 1 = Pink, 2 = White, 3 = Tone, Null = Current state
Amplitude -60 to +20 amplitude in dB; NULL for type 0
Frequency 20 to 20,000 frequency in Hz (only needed when using tone
generation)
Example:
#56 SIGGEN 1 M 2 0
On XAP 800 unit 6 (
#56
), the signal gen-
erator (
SIGGEN
) is set to input at mic (
M
) channel
1
with white noise (
2
) at
0
dB.
Appendices ~ Appendix E: Serial Commands