37
System Configuration ~ Inputs and Outputs
Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760
Bandwidth. Bandwidth establishes the difference between the upper and lower
points of a filter’s audio passband.
Bypass. The Bypass box, when selected, bypasses the selected filter.
Phase. Phase generates—on the graph—the phase relationship of the graphed
frequency response.
Bypass All. Bypass All bypasses all filters.
Add Filter. Add Filter adds a filter to the graph, centered at 1kHz and 0dB.
Remove Filter. Remove Filter removes the selected filter from the graph.
Table View
Table View toggles between the Graph and the Table views of the Inputs 1-8 Filter
window. The Table view displays the selected filter settings in table format. You can
configure filters from this view as well as in the graph view.
To configure filters
1. In either the graph or table view, select the filter type from the Typelist.
Note that the configurable filter parameters displayed depend on the
selected filter type.
2. Click Add Filter to add a filter to the graph or table.
3. Configure filter parameters using the previously described lists. If you are
using the graph view, you can click on the node and drag it to the location
you desire on the graph.
4. Click Close to exit.
Figure 3.33. Filter Graph window, table view