Cleveland Range KET-3-T Recommended Cleaners For Specific Situations, Marine Lock, Disassembly

Models: KET-3-T

1 28
Download 28 pages 45 Kb
Page 9
Image 9
RECOMMENDED CLEANERS FOR SPECIFIC SITUATIONS

RECOMMENDED CLEANERS FOR SPECIFIC SITUATIONS

Job

Cleaning Agent

Comments

Routine Cleaning

Soap, Ammonia

Apply with cloth or

 

Detergent, Medallion

sponge

Fingerprints

Arcal 20, Lac-O-Nu

Provides barrier film

& Smears

Ecoshine

 

Stubborn Stains

Cameo, Talc, Zud

Rub in direction

& Discolouration

First Impression

of polish lines

Grease & Fatty Acids,

Easy-Off, De-Grease It

Excellent removal

Blood, Burnt-On Foods

Oven Aid

on all finishes

Grease & Oil

Any good commercial

Apply with sponge

 

detergent

or cloth

Restoration/

Benefit, Super Sheen

 

Passivation

 

 

 

 

 

MARINE LOCK

Use a small nylon bristle brush to remove food and debris from pivot point. If lock is still sticking have maintenance disassemble and clean pieces individually and reassemble.

Latch

Shoulder Bolt

Locknut

Lockwasher

Disassembly

1.Disconnect power from kettle.

2.Remove console cover from top of kettle's console.

3.Remove locknut and lockwasher from inside console.

4.Remove shoulder bold from latch.

5.Clean all parts.

Re-Assembly

6.Apply locktight to shoulderbolt where illustrated. Replace shoulder bolt and latch and tighten firmly.

Carefully apply locktight to the final two threads.

7.Replace lockwasher and locknut inside the console and tighten firmly.

8.Test Marine Lock. See Marine Lock Testing Procedure (page 19).

9.Replace console cover.

7

Page 9
Image 9
Cleveland Range KET-3-T manual Recommended Cleaners For Specific Situations, Marine Lock, Disassembly, Re-Assembly