Maintenance

4.2.Quick service guide

MODELS: GLX

 

 

TECHNICAL ISSUE

CAUSE

SOLUTION

 

Delimer switch in delime position

Flip to NORMAL position

Wash Pump motor will not shut off

Faulty delimer switch

Replace switch, P/N 00475.30

 

Faulty manual drain switch

Replace switch, P/N 03406.62

 

Faulty contactor

Replace contactor, P/N 00404.82

Continues cycles

Faulty #1 micro switch (start/stop)

Replace switch, P/N 00411.00

 

Faulty start/fill switch

Replace switch, P/N 03470.01

 

Faulty #1 micro switch

Replace switch, P/N 00411.00

 

 

Add water to tank to activate float switch, adjust

 

Low water level inside machine

water cam on timer

Sustainer heater not working

Faulty float switch

Replace switch, P/N 13463.10

 

Machine not level

Level machine

 

Faulty ice cube relay

Replace relay, P/N 00631.00

Machine does not drain

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

 

Faulty drain valve

Replace drain valve, P/N 04103.00

Does not hold water

Faulty #3 micro switch (drain)

Replace switch, P/N 00411.00

 

Clogged or defective drain valve

Clean and/ or replace drain valve, P/N 04103.00

 

 

Clean and replace valve diaphragm, P/N

Tank overflows overnight

Debris in water Solenoid Valve

00707.00

 

Dirty or defective vacuum breaker kit

Clean or replace internal parts, P/N 03623.00

Water leaks out of Vacuum Breaker

assy

 

 

 

 

Faulty check valve

Replace check valve, P/N 00715.00

 

Male/ female plug on the back of control

Secure plug

 

drawer is loose

 

 

 

 

Wash Pump motor not running

Faulty door reed switch

Replace reed switch, P/N 00557.55

 

Faulty 7th micro switch

Replace switch, P/N 00411.00

 

Faulty motor contactor

Replace contactor, P/N 00404.82

 

Faulty Start/Fill Switch

Replace switch, P/N 03470.01

Timer does not rotate

Faulty #1 micro switch

Replace switch, P/N 00411.00

 

Faulty timer motor

Replace motor assembly, P/N 00501.00

 

Faulty #4 Micro switch

Replace switch, P/N 00411.00

 

Debris inside water solenoid valve or

Clean and replace valve diaphragm, P/N

 

Faulty valve

Machine does not fill

00707.00

 

 

Faulty water solenoid coil

Replace solenoid coil, P/N 00738.10

 

Delimer switch in wrong position

Switch to NORMAL position

Sanitizer pump does not run

Faulty 5th micro switch

Replace switch, P/N 00411.00

 

Faulty sanitizer pump motor

Replace motor, P/N 00416.00

0204

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.00A –08/04/05

11

PAGE

Page 12
Image 12
CMA Dishmachines GL-X manual Quick service guide, Models GLX Technical Issue Cause Solution