Maintenance

4.3.Troubleshooting

PROBLEM

LIKELY CAUSE

SOLUTION

Machine inoperative

Power off at circuit breaker

Reset circuit breaker

 

Defective power switch

Replace power switch

 

 

P/N: 00433.10

 

Defective timer assembly motor

Replace timer assembly motor

 

 

P/N: 00501.00

Pump Motor inoperative

Door is open

Close door

 

Control drawer is pulled out

Secure control drawer

 

Defective reed (door) switch

Replace reed (door) switch

 

 

P/N: 00557.55

 

Defective timer assembly

Replace timer assembly*

 

(Cam 7)

P/N: 00408.80

 

Defective pump motor contactor

Replace contactor

 

 

P/N: 00404.82

 

Defective pump motor

Replace pump motor

 

 

P/N: 00201.00

Pump Motor runs with door

Defective reed (door) switch

Replace reed (door) switch

open

 

P/N: 00557.55

 

Defective pump motor contactor

Replace contactor

 

 

P/N: 00404.82

 

Delime switch is on

Turn off delime switch

Motor runs continuously

Delime switch is on

Turn off delime switch

Sustainer Heater

Defective thermostat on heater

Replace heater

 

 

P/N: 04109.10

 

Defective heater relay

Replace heater relay

 

 

P/N: 00631.00

 

Defective timer assembly

Replace timer assembly *

 

(Cam 8)

P/N: 00408.80

 

Defective heater

Replace heater

 

 

P/N: 04109.10

 

 

 

 

Defective float switch

Replace float switch

 

 

P/N: 13463.00

 

Float switch not actuated

Fill wash tank completely

 

 

Level machine

 

 

 

Sustainer Heater

Defective thermostat on heater

Replace heater

 

 

P/N: 04109.10

 

Defective timer assembly

Replace timer assembly *

 

(Cam 8)

P/N: 00408.80

 

Defective heater relay

Replace heater relay

 

 

P/N: 00631.00

*The timer assembly motor (P/N: 00501.00) or micro switches (P/N: 00411.00) can be replaced independently if that is the only component that has failed.

MODEL GL-X INSTALLATION & OPERATION MANUAL Rev. 1.00A –08/04/05

12

PAGE

Page 13
Image 13
CMA Dishmachines GL-X manual Troubleshooting