P R O G R A M M I N G

 

 

!RFID LEDFLSH

 

Function

Controls the transmission of a ‘Success’ or ‘Failure’

 

indication to the LED display during and at the

 

very end of any CPL-RFID command’s execution.

Explicit Form

!RFID LEDFLSH ON/OFF/ACCUM

Parameters

ON

Flashes LED (Green for Success) or (Red

 

 

for Failure) after any CPL-RFID

 

 

command completion

 

OFF

Does NOT flash any LED after CPL-

 

 

RFID command completions. The LED

 

 

normally remains OFF during a label-

 

 

format execution until the printer is

 

 

ready for the next label or command

 

 

where LED is set Green

 

ACCUM

Does NOT flash any LED until after the

 

 

entire label- format has completed

 

 

execution. If all CPL- RFID commands

 

 

completed successfully, the LED is

 

 

flashed GREEN and OFF three times.

 

 

If any CPL-RFID command failed, the

 

 

LED is flashed RED and OFF three

 

 

times.

Response

No specific response

Command Type

RFID Setup/Debug Command

Example

To Printer:

 

 

!RFID LEDFLSH OFF

NOTE: All CPL-RFID Configuration-Setup Commands are processed outside the context of a standard CPL Label-Format (i.e. CPL beginning with a header-line ‘! 0 100 nnn 1’ and ending with ‘END’). Attempts to use CPL-RFID Configuration-Setup Commands within a Label-Format result are ignored without indication.