P R O G R A M M I N G

 

 

 

WT

 

 

Function

Write Tag. This command stores the quoted data to

 

the RFID-Tag currently positioned over RFID

 

Reader/Writer H/W. The data will begin storage at

 

the ss Tag-block and extend to and Zero pad any

 

unused bytes within the ending block.

Explicit Form

WT ss “data”

Parameters

ss

Starting block to begin reading octets

 

 

(bytes)

 

“data” Collection of data octets to be written to

 

 

the RFID tag. The size of "data" must

 

 

be in the range of 1-255 octets.

Response

No specific response

Command Type

RFID Standard Command

Example

To Printer:

 

! 0 100 800 0

 

DELIMIT $

 

WT 0 "123-1234-123"

WT 4 "John Q. Public"

WT 10 "Cardiac Care Unit"

RT 0 3 "A" 33

RF HOST "$RF 33$"

END

From Printer:

123-1234-123

NOTE: In this initial Adv-LX RFID Printer, the Skyetek- M1 Reader/Writer Module limits individual Read or Write transfers to/from the RFID-Tags to 64-bytes maximum. CPL command lines are naturally limited to 256-bytes. Therefore, 4 separate 64-byte WT commands must be executed to fill a 256-byte RFID- Tag,

Copyright © 2004, Cognitive.