Operation continued.

Operation continued.

Lighting Instructions for HEATER continued.

3.Pilot Light will ignite and be visible through Pilot Viewing Port (flame may be difficult to see in broad daylight). Continue to push Heater Control Knob in for 30 to

60seconds after pilot is on, then release knob. Pilot Light must remain on, if not return to

step 1.

Pilot

 

Pilot

Viewing

 

Port

Port

 

 

 

 

 

 

Note: If pilot fails to remain lighted, all valves should be closed and a waiting period of at least 5 minutes should pass before attempting to light.

4.Rotate Heater Control Knob to ON position. Heater burner will light and be visible through screen of heater. If Main burner does not light, turn off Heater Control Knob and return to Step 1.

Heater

 

Control

Igniter

Knob

Lighting Instructions for LIGHT

1.Push in and rotate Light Control Knob to the ON position while pushing the Igniter Button until BOTH mantles are lighted.

Note: If BOTH mantles are not lighted within 5 seconds, turn Light Control Knob to OFF position. All controls should be turned to the OFF position and a period of at least 5 minutes should pass before reattempting to light burners.

Match Lighting Instructions for HEATER

1. Turn cylinder valve on.

 

2. Push in and rotate (counter

 

 

clockwise) Heater Control Knob

 

 

to the Pilot position and release.

 

 

 

 

 

 

3.Use a long match. Locate Pilot Port directly above center glass panel.

4.Light a long fireplace match (minimum 4" long) and insert into Pilot Port, then push in and hold Heater Control Knob.

5.Pilot light will ignite and be visible from Pilot Port or Pilot Viewing Port. Continue to push Heater Control Knob in for 30 to 60 seconds after pilot is on, then release knob. Pilot light must remain on, if not return to Step 1.

Pilot

Port

2.Mantles will light and begin to glow which can be seen through the windows. If the mantles do not light or fail to remain lighted turn OFF Light Control Knob and return to Step 1.

Unit can be operated with heater & light both operating or either operating separately.

Light

Control

Knob

Igniter

Note: If pilot fails to remain lighted, all valves should be closed and a waiting period of at least 5 minutes should pass before attempting to light.

6.Rotate Heater Control Knob to ON position. Heater burner will light and be visible through screen of heater. If Heater burner does not light, turn off Heater Control Knob and return to Step 1.