Coleman 5075 Series, 5070 Series manual Symptom Possible Cause, Remedy, HOW Often HOW to

Models: 5070 Series 5075 Series

1 44
Download 44 pages 3.38 Kb
Page 11
Image 11

WARNING

TROUBLE-

Never attempt to service heater while it is plugged in, connected to propane

SHOOTING

 

supply, operating or hot. Severe burns and electrical shock can occur.

 

SYMPTOM

POSSIBLE CAUSE

Fan does not turn

No electrical power to heater

when heater is

 

plugged in.

 

 

Fan blades bent

 

Defective motor

Heater will not

User did not follow prepara-

ignite.

tion or operation instruc-

 

tions properly

 

No spark at electrode. To test

 

for spark, follow step 9 un-

 

der Replacing Electrode,

 

page 13. If you see spark at

 

ignitor, have heater serviced

 

by qualified service person.

 

If no spark seen:

 

A) Loose or disconnected

 

ignitor wire

 

B) Wrong spark gap

 

C) Piezo ignitor loose

 

D) Bad electrode

 

E) Bad piezo ignitor

 

F) Bad electronic module

Heater shuts down

High surrounding air tem-

while running.

perature causing thermal

 

limit device to shut down

 

heater.

 

Restricted air flow

REMEDY

Check voltage to electrical outlet. If voltage is good, check heater power cord for breaks.

Replace fan. See Replacing Fan, Page 13.

Replace motor. See Replacing Motor, page 12.

Repeat preparation and opera- tion instructions. See Preparation, pages 6 & 7 and Operation, pages 7, 8 & 9.

A)Check ignitor wire. Tighten or reattach loose ignitor wire. See page 5 for ignitor

wire location.

B)Set gap between ignitor electrode and target plate to .20" (0.5 cm).

C)Tighten piezo ignitor to base

of heater.

D)Replace electrode. See Replacing Electrode, page 13.

E)Replace ignitor.

F)Replace electronic module.

This can happen when running heater in temperatures above 85°F (29°C). Run heater in cooler temperatures.

Check heater inlet and outlet. Remove any obstructions.

ENGLISH

WARNING

Damaged fan

Replace fan. See Replacing Fan,

Use only in areas

 

page 13.

free of high dust

Excessive dust or debris in

Clean heater. See Maintenance,

content.

surrounding area

pages 9 & 10.

ITEM

HOW OFTEN

HOW TO

PREVENTIVE

Fan

Clean every 500 hours of

See Fan, page 10

MAINTENANCE

 

operation or as needed.

 

SCHEDULE

Electrode

Clean and regap every 500

See Electrode, page 10

 

 

hours of operation or replace

 

Continued

 

as needed.

 

11

Page 11
Image 11
Coleman 5075 Series, 5070 Series manual Symptom Possible Cause, Remedy, HOW Often HOW to