Coleman 5070 Series, 5075 Series manual Maintenance, Electrode

Models: 5070 Series 5075 Series

1 44
Download 44 pages 3.38 Kb
Page 10
Image 10

MAINTENANCE

Continued

6.FAN - Clean every 500 hours of operation or as needed.

A.Remove screws along each side of heater and on top of the motor guard using a Phillips screwdriver. These screws attach top and lower shells together.

B. Lift top shell off.

C. Lift out motor/guard assembly.

IMPORTANT: Do not allow the motor/guard assembly to rest on the fan or damage may be caused to the blades.

D.Clean fan using soft cloth moistened with kerosene or solvent. Dry fan thoroughly. Clean inside the shell adjacent to where the fan runs.

E.Replace motor/guard assembly and top shell.

7.ELECTRODE

A.Make sure gap between electrode wire and burner nozzle is .20 (0.5 cm) to

.25" (0.6 cm). Access electrode from inside combustion chamber. No other

maintenance is needed for electrode.

Continued

10

Page 10
Image 10
Coleman 5070 Series, 5075 Series manual Maintenance, Electrode