Technical Reference Guide

5.4.2 SERIAL INTERFACE PROGRAMMING

Programming the serial interfaces consists of configuration, which occurs during POST, and control, which occurs during runtime.

5.4.2.1 Serial Interface Configuration

The serial interface must be configured for a specific address range (COM1, COM2, etc.) and also must be activated before it can be used. Address selection and activation of the serial interface are affected through the PnP configuration registers of the LPC47B357 I/O controller.

The serial interface configuration registers are listed in the following table:

Table 5–8. Serial Interface Configuration Registers

 

Table 5-8.

 

 

Serial Interface Configuration Registers

 

Index

 

 

Address

Function

R/W

30h

Activate

R/W

60h

Base Address MSB

R/W

61h

Base Address LSB

R/W

70h

Interrupt Select

R/W

F0h

Mode Register

R/W

NOTE:

Refer to LPC47B357 data sheet for detailed register information.

Compaq Evo and Workstation Personal Computers 5-9

Featuring the Intel Pentium 4 Processor

Second Edition - January 2003

Page 96
Image 96
Compaq W4000 manual Serial Interface Programming, Serial Interface Configuration Registers, Function