6. Power Supply Alarm Reset button
You can push the power supply reset button to stop the power supply buzzer alarm.
7.AC power input socket 1 ~ 2 (From left to right)
8.Power Supply Unit 1 ~ 2 (From left to right)
Three power supplies (power supply 1 and power supply 2) are located at the rear of the subsystem. Turn on the power of these power supplies to power- on the subsystem. The “power” LED at the front panel will turn green.
If a power supply fails to function or a power supply was not turned on, the “” Power fail LED will turn red and an alarm will sound. An error message will also appear on the LCD screen warning of power failure.
9.
The subsystem is equipped with one 10/100 Ethernet RJ45 LAN port. You use
Link LED: Green LED indicates ethernet is linking.
Link speed LED: Orange LED indicates the link speed is 100Mbps. The LED will not blink when the link speed is 10Mbps.
10. Uninterrupted Power Supply (UPS) Port
The subsystem may come with an optional UPS port allowing you to connect a UPS device. Connect the cable from the UPS device to the UPS port located at the rear of the subsystem. This will automatically allow the subsystem to use the functions and features of the UPS.
11. Monitor Port
The subsystem is equipped with a serial monitor port allowing you to connect a PC or terminal.