To view the RAID subsystem controller’s hardware monitor information, move the mouse cursor to the main menu and click the Hardware Monitor link. The Hardware Information screen appears.
The Hardware Monitor Information provides the temperature, fan speed (chassis fan) and voltage of the internal RAID subsystem. All items are also unchangeable. The warning messages will indicate through the LCD, LED and alarm buzzer.
Item | Warning Condition | ||
|
|
| |
Controller Board Temperature | > 60 Celsius |
| |
|
| ||
HDD Temperature | > 55 Celsius | ||
|
|
| |
Controller Fan Speed | < 2600 RPM |
| |
|
|
|
|
Power Supply +12V | < 10.8V | or | > 13.2V |
|
|
| |
Power Supply +5V | < 4.5V | or > 5.5V | |
Power Supply +3.3V | < 2.97V | or | > 3.63V |
|
|
|
|
DDR Supply Voltage +2.5V | < 2.25V | or | > 2.75V |
|
|
|
|
CPU Core Voltage +1.3V | < 1.17V | or | > 1.43V |
|
|
| |
DDR Termination Power +1.25V | < 1.125V or | > 1.375V | |
|
|
|
|
Configuring |