OPTICAL SOLUTIONS FOR DIVERSE NEEDS AND ENVIRONMENTS.
Envoy offers three optical distributions and a variety of light control media to optimize lighting performance and comply with local lighting ordinances.
The standard Envoy system features the main reflector contributing to both horizontal and vertical illumination. The upper reflector
contributes 10% uplight, reducing the visual cave effect within the parking structure.
DESIGN PRACTICES
Lighting design for parking structures normally follows specific published guidelines and design practices as defined by the Illuminating Engineering Society of North America [IESNA]. IESNA publishes recommended guidelines to help facilitate garage lighting design. The following minimum guidelines are established for safety and security of pedestrians and property within the space.
RECOMMENDED MAINTAINED ILLUMINANCE VALUES FOR PARKING GARAGES
Horizontal Illuminance [On Floor] | Minimum Horizontal Footcandles [fc]* | Vertical Illuminance [60” Above Floor] | Minimum Vertical Footcandles [fc]* |
Basic | 1.0 | Basic | 0.5 |
Ramps Day | 2.0 | Ramps Day | 1.0 |
Ramps Night | 1.0 | Ramps Night | 0.5 |
Entrance Areas Day | 50 | Entrance Areas Day | 25 |
Entrance Area Night | 1.0 | Entrance Areas Night | 0.5 |
Stairways | 2.0 | Stairways | 1.0 |
*NOTE: IES Recommended Practices
In addition to the amount of light measured on the work plane, uniformity of light must be balanced as well. As with minimum footcandle values listed on the above table, the maximum/minimum uniformity ratio within the space is an important element in minimizing eyestrain and creating an inviting and safe environment. The IESNA recommended maximum/minimum uniformity ratio is no greater than 10:1.
DIRECTION
OF TRAFFIC
ROUND [RD] | CONCENTRATED DOWN LIGHT [CD] | DRIVE LANE SHIELD [DLS1] |
DIRECTION OF TRAFFIC
DIRECTION OF TRAFFIC
|
|
|
|
|
|
|
|
|
Garage Exterior |
| Garage Exterior |
DRIVE LANE SHIELD [DLS2] | HOUSE SIDE SHIELD 120° [HS] | HOUSE SIDE SHIELD 180° [HS] |