Cooper Lighting Epl Envoy, Ordering Information, Product, Lamp Wattage, Lamp Type, Ballast

Models: Envoy

1 24
Download 24 pages 9.89 Kb
Page 23
Image 23
EPL ENVOY
ACCESSORIES 25 [order separately/ replace XX with color designation] EPL/PBG-XX=Balanced Pendant
Box/Bird Guard
EPL/WM-XX=Wall Mount Arm26 EPL/HS=House Side Shield Up and
Downlight 120° Coverage [HID Lamps Only] 27
EPL/HSCF=House Side Shield Up and Downlight 120° Coverage [CF Lamps Only] 27
EPL/DLS=Drive Lane Shield 28
VRSD=T20 Torx CPR Tamper Resistant Screwdriver
EPL/TL=Task Light Field Install Kit for 120V MR16 lamp [GU10 Base]
EPL/TL12V=Task Light Field Install Kit for 12V MR16 lamp [GU5.3 Base]

EPL ENVOY

ORDERING INFORMATION

SAMPLE NUMBER: EPL-175-MP-MB-MT-TG-AP-L-EM/SC

PRODUCT

LAMP WATTAGE

CF

LAMP TYPE

BALLAST

 

VOLTAGE 5

DISTRIBUTION

COLOR

OPTIONS +

FAMILY

MH 1

HPS

MH=Metal Halide

MB=Magnetic

120=120V

RD=Round

[add as

ACCESSORIES

EPL=Envoy

175=175W

70=70W

84= [2] 42W

MP=Pulse Start

Ballast

3

208=208V

SQ=Square

suffix/must

[See Below]

Parking

MP

2

100=100W

114= [2] 57W

Metal Halide

 

240=240V

TG=Rectangular

 

 

EB=Electronic

specify]

 

Luminaire

70=70W

150=150W

126= [3] 42W

HPS=High

Ballast 4

277=277V

 

AP=Grey

 

 

100=100W

Induction

140= [2] 70W

Pressure

 

 

480=480V

 

BK=Black

 

 

150=150W

85= 85W

168= [4] 42W

Sodium

 

 

DT=Dual-Tap w/277V 6

 

 

175=175W

 

 

CF=Compact

 

 

MT=Multi-Tap w/277V 6

BZ=Bronze

 

 

200=200W

 

 

Fluorescent

 

 

TT=Triple-Tap w/347V 6

WH=White

 

 

 

 

 

 

QL=Induction

 

 

 

 

 

 

OPTIONS + ACCESSORIES [Must be listed in the order shown and separated by a dash]

OPTIONS 7 [add as suffix] CD=Concentrated Downlight

[Restricts Uplight 360°] 8 CT=Conduit Taps [Qty [2] 3/4"

NPSM] 9

F=Single Fuse [Specify 120, 277 OR 347 in "Voltage" column] FF=Double Fuse [Specify 208, 240 OR 480 in "Voltage"

column] HA=40° C Ambient 10 HL=Hi/Low Dimming 11 L=Lamp Included, HID

LF=Lamp Included, Compact Fluorescent

LQ=Lamp Included, Quartz Halogen DCB

PH=Upper Polycarbonate Lens

[Near Aluminum Back Housing]

PL=Lower Polycarbonate Lens QD=Quick Disconnect[s]

[between cover/housing] TMB=Trunnion Mount with

Connection Box [some assembly required]

TMC=Trunnion Mount with Power Cord [some assembly required]

TR=Tamper Resistant [Torx T20 CPR]

WL=24” Lead Wires

STANDBY + EGRESS LAMP OPTIONS

Q=Quartz Restrike [hot restrike only, 120v T4 DCB quartz lamp] 12

EM=Quartz Time Delay [hot and cold restrike, 120v T4 DCB quartz lamp] 12 EM/SC=Emergency Separate Circuit [120v T4 DCB quartz lamp] 12 __CFSC=CF [1] Separate Circuit [Specify 52, 64 or 84, supplied with

120-277v electronic ballast] 13

__CFHR=CF Hot Restrike Relay [Specify 52, 64 or 84, supplied with 120-277v electronic ballast] 13

__CFTR=CF Time Delay Relay [Hot and Cold Restrike] [Specify 52, 64 or 84, supplied with 120-277v electronic ballast] 13

CFRB=CF Remote Battery Pack, sockets accommodate 26-42w CF lamps [Battery Pack specified/supplied/wired by Others] 13

36CFIB=CF Integral Battery Pack operates [2] 18w CFL 14 CFRBT=CF Remote Battery Pack with Time Delay Relay, sockets

accommodate 26-42w CF lamps [Battery Pack specified/supplied/wired by Others] 13

36CFIBT=CF Integral Battery Pack operates [2] 18w CFL with Time Delay Relay 14

RBP=Remote Battery Pack, sockets accommodate 26-42w CF lamps [CF units only; Battery Pack specified/supplied/wired by Others] 15

42IBP=Integral Battery Pack, [1] 42w CF lamp standby 16

42ICB=Integral Cold Weather Battery Pack, [1] 42w CF lamp standby 17

4CF3=4 CF lamps wired as 3 independent circuits, 3 electronic ballasts [2 lamps/1 lamp/1 lamp] 18 4CF2=4 CF lamps wired as 2 independent circuits, 2 electronic ballasts [2 lamps/2 lamps] 18 3CF2=3 CF lamps wired as 2 independent circuits, 2 electronic ballasts [2 lamps/1 lamp] 19 2CF2=2 CF lamps wired as 2 independent circuits, 2 electronic ballasts [1 lamp/1 lamp] 20 TL__=Task Light 120v MR16 [GU10 Twist Lock Base] 21

2TL__=[2] Task Lights 120v MR16 [GU10 Twist Lock Base] 21

TLQ__=Task Light 120v MR16 wired to Hot Restrike Relay [GU10 Twist Lock Base] 22 2TLQ__=[2] Task Lights 120v MR16 wired to Hot Restrike Relay [GU10 Twist Lock Base] 22 TLEM__=Task Light, 120v MR16 wired to Time Delay Relay [GU10 Twist Lock Base] 22 2TLEM__=[2] Task Lights, 120v MR16 wired to Time Delay Relay [GU10 Twist Lock Base] 22 TL12V__=Task Light, 12v MR16 [GU5.3 Bi-Pin Base] 23

2TL12V__= [2] Task Lights, 12v MR16 [GU5.3 Bi-Pin Base] 23

TL__MR__=Task light with transformer [GU5.3 Bi-Pin Base, specify 50 or 75w lamp, specify 120 or 277v transformer] 24

DIMENSIONS

STANDARD COLORS

 

 

 

WATTAGE TABLE

16 3/8ORDERING INFORMATION (415mm)

 

 

 

AP

 

 

 

Grey

 

 

 

WH

13

 

1/2

White

 

 

(334mm)

BK

 

 

 

 

 

 

Black

BZ

Bronze

SHIPPING DATA

Net Weight [21 lbs.] Volume [2.1 cu. ft.]

LAMP TYPE

WATTAGE

Metal Halide

175W

High Pressure Sodium

70, 100, 150W

Pulse Start Metal Halide

70, 100, 150, 175, 200W

Compact Fluorescent

[2] 42, [2] 57, [3] 42, [2] 70, [4] 42W

Induction

85W

CERTIFICATIONS

IP66 Rated

40°C Ambient Temperature*

NOTE: * Varies by model.

C-UL/U.L. 1598 Listed Wet Location

 

2G Vibration Tested

 

ISO 9001

 

NOTES: 1 Metal Halide lamps with probe start circuit. 2 Pulse Start Metal Halide circuit includes igniter. 3 HID lamps only. 4 Must specify voltage. EB standard on CF. Available integrally in HID 100w MP [max] and 85w QL. HID availability may vary by lamp source, wattage and voltage. For HID wattages higher than 100w, remote mount ballast possible within 5 feet of unit. Consult customer service. 5 Product also available in non-US voltages and 50Hz for international markets. Must specify voltages for battery packs. Consult your customer service representative for availability and ordering information. 6 Dual tap ballast is 120/277V wired 277V. Multi-tap ballast is 120/208/240/277V wired 277V. Triple tap ballast is 120/277/347 wired 347V. 7 Add as suffix in order shown. 8 Requires option PL for use in 40°C application with HID lamps 175-200w. 9 CT option required for through branch wiring. Through branch wiring is not available with specific configurations including HID CF egress options and fixtures with integral battery pack. 10 Not available with 85w QL and options using CF lamp sources. Requires option PH on 200-175w HID. 11 Available in 150-200w MP, 175w MH and 70-150w HPS. Operates on 24VDC type output control module. Circuit relay board is mounted internal to fixture housing with leads exiting back. Requires low voltage wires to control module to be routed in conduit. 12 For use with HID primary lamp only. Quartz lamp 100w maximum. 13 For use with 175w [max] or less HID primary lamp only. Requires option “CT”. Uses [2] 4 pin CF lamps. CF minimum starting temperature 0°F [-18°C]. RB requires “CT” option 14 For use with 150w [max] or less HID primary lamp only. Uses [2] 18w 4 pin CF lamps. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 15 For use with 168, 126, 84 CF units only. Requires option “CT”. Battery supplied by others. Standby lamp combination wired by others. 16 For use with 168, 126, 84 CF units only. Battery rated minimum 32°F/ 0°C. Specify 120 or 277v in "VOLTAGE" column. 17 For use with 168, 126, 84 CF units only. Battery rated minimum -4°F/ -20°C. Specify 120 or 277v in "VOLTAGE" column. 18 For use with 168 CF only. 19 For use with 126 CF only. 20 For use with 84, 114, or 140 CF only. 21 Task Light[s] with separate leads through back of fixture. Specify TL location by adding to back of option logic [ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 22 For use with HID lamps only. Task Light[s] supplied wired to relay. Specify TL location by adding to back of option logic

[ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 23 Task Light[s] supplied with separate leads through back of fixture for connection to 12v circuit or battery system. Specify TL location by adding to back of option logic [ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 24 Task Light max quantity [1], supplied with transformer. Specify TL location by adding to back of option logic [ex.2TLA1A2]-see diagram. Some assembly required, order lamps separately. 25 Order separately, replace XX with color suffix 26 Luminaire requires option WL. 27 Order additional shield set for more coverage [ex. 2 sets for 180° shielding] Maximum of 2 sets total. 28 Placed towards side of oncoming traffic for 60° shielding coverage. Order [2] for 2-Way traffic lanes. 29 Some options and accessories are not available in all configurations. Consult your customer service representative for ordering information. 30 Specifications and dimensions subject to change without notice.

Page 23
Image 23
Cooper Lighting manual Epl Envoy, Ordering Information, Product, Lamp Wattage, Lamp Type, Ballast, Voltage, Distribution