REPLACEMENT OF CARBON BRUSHES (Fig. 20)
Replacement brush sets are available through Sears Parts and Repair Centers°
!o Unplug the router motor before inspecting or replacing brushes.
2.Replace both carbon brushes when either has less than
3.Using a slotted screwdriver, remove the black plastic cap on each side of the router motor (Fig° 20) and carefully withdraw the
tOTE:To reinstall the same brushes, make sure the brushes go back in the
same way they came out.This will avoid
4, Insert new brush assemblies into guide channels, with the carbon part going in first, being certain to fit the two metal "ears" into their slots in the channel (Fig. 20).
5 Remember to replace both end caps after inspecting or servicing brushes. Tighten the caps snugly, but do not
Fig. 20
Cap
Ears
I ZmotorWARNING:from the powerFor yoursourcesafety,beforeALWAYSperformingturn offanyswitchmaintenanceandunplugorcleaning,router
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient amount of