To Replace Regulator

1.Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.

2.Unplug unit.

3.Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.

4.Remove the regulator.

Outlet

Pressure

Gauge

Regulator Quick

Connect

5.Apply pipe sealant tape to the nipple.

Nipple

6.Assemble the regulator and orient as shown.

Regulator

NOTE: Arrow indicates flow of air. Make sure it is pointing in the direction of air flow.

7.Reapply pipe sealant to outlet pressure gauge and quick connect.

Regulator

Arrow

8.Reassemble outlet pressure gauge and quick connect. Orient outlet pressure gauge to read correctly. Tighten quick connect with wrench.

17- ENG