6.After 20 minutes, close the drain valve (clockwise). The air receiver will fill to
The compressor is now ready for use.
Before Each Start-Up:
1.Place On/Auto/Off lever to “OFF”.
2.Pull regulator knob out, turn counterclockwise until it stops. Push knob in to lock in place.
3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect.
Too much air pres- sure causes a haz- ardous risk of bursting. Check the
manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pres- sure rating.
How to Start:
1.Turn the On/Auto/Off lever to “AUTO” and allow tank pressure to build. Motor will stop when tank pressure reaches
2.Pull the regulator knob out and turn clockwise to increase pres- sure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.
NOTE: Always operate the air com- pressor in
D24910 | 16- ENG |