Motor

This motor has a manual thermal overload protector. If the motor over- heats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart:

1.Place the On/Auto/Off lever in the Off postion.

2.Allow the motor to cool.

Reset

Button

3.Depress the red reset button on the motor.

4.Place the On/Auto/Off lever in the On/Auto postion to restart the motor.

Pressure Switch - Replacement

Pressure loads beyond design lim-

its may cause tank rupture or explosion. Pressure switch opera- tion is related to motor HP, tank rating, and safety valve setting. Do not attempt to adjust, remove, or defeat the pressure switch, or change and modify any pressure control related device. If replace- ment is necessary the same rated switch must be used. Contact a trained service technician for replacement.

To Replace Regulator

1.Release all air pressure from air tank. See “To Drain Tank” in the Maintenance section.

2.Unplug air compressor.

3.Remove the regulator ring and remove the console cover.

Regulator

Cover

Ring

 

4.Using an adjustable wrench loosen pressure relief tube nut at air tank and pressure switch.

5.Lift retaining clip from handle and remove handle.

Retaining clip

Handle

6.Using an adjustable wrench, rotate the pressure switch assembly as shown.

Tank

RegulatorPressure

Gauge

Outlet

Quick

Pressure

Connect

Gauge

 

 

 

7.Remove the outlet pressure gauge, tank pressure gauge, and quick connect (if equipped) from the regulator.

8.Remove the regulator.

9.Apply pipe sealant tape to the nipple.

21- ENG

D24910

Page 21
Image 21
Craftsman 919.19541 owner manual Motor, Pressure Switch Replacement, To Replace Regulator