PROBLEM | CAUSE | CORRECTION | ||||
|
|
|
|
|
| |
Compressor is not supply- | Compressor is not large enough | Check the accessory air requirement. If it is higher | ||||
ing enough air to operate | for air requirement. | than the SCFM or pressure supplied by your air | ||||
accessories. |
| compressor, you need a larger compressor. | ||||
|
| Restricted air intake filter. | Clean or replace air intake filter. Do not operate | |||
|
|
| the air compressor in any paint spray or drywall | |||
|
|
| sanding area. | |||
|
| Hole in hose. | Check and replace if required. | |||
|
| Check valve restricted. | Remove and clean, or replace. | |||
|
| Air leaks. | Tighten fittings. | |||
|
| Loose belt. | Adjust belt tension. | |||
|
| Restricted or defective check valve. | Remove and clean or replace. | |||
|
|
| ||||
Motor will not run or restart. | Present tank pressure exceeds | Motor will start automatically when tank pressure | ||||
|
| pressure switch | drops below | |||
|
| Fuse blown, circuit breaker tripped. | 1. Check fuse box for blown fuse and replace, if | |||
|
|
|
| necessary. Reset circuit breaker. Do not use a | ||
|
|
|
| fuse or circuit breaker with higher rating than | ||
|
|
|
| that specified for your particular branch circuit. | ||
|
|
| 2. | Check for proper fuse; only Time Delay fuses | ||
|
|
|
| are acceptable. | ||
|
|
| 3. Check for low voltage conditions and/or | |||
|
|
|
| proper extension cord. | ||
|
|
| 4. | Disconnect the other electrical appliances | ||
|
|
|
| from circuit or operate the compressor on its | ||
|
|
|
| own branch circuit. | ||
|
|
| 5. | Check for loose electrical connections. | ||
|
| Motor overload protection switch | Let motor cool off and overload switch will | |||
|
| has tripped. | auto- matically reset. | |||
|
| Possible defective motor or | Return to Sears Service Center for inspection or | |||
|
| capactior. | replacement, if necessary. | |||
|
| Paint spray on internal motor | Have compressor checked at Sears Service Center. | |||
|
| parts. | Do not operate the compressor in the paint spray | |||
|
|
| area. See flammable vapor warning. | |||
|
| Check valve stuck open, putting | Remove and clean, or replace the check valve. | |||
|
| pressure on head. |
|
|
|
|
|
| Pressure release valve on pressure | Bleed the line by pushing the lever on the pressure | |||
|
| switch has not unloaded head | switch to the "O" position; if the valve does not | |||
|
| pressure. | open, replace it. | |||
|
|
|
|
| ||
Regulator knob continuous | Dirty or damaged regulator | Replace regulator. | ||||
air leak. Regulator will not | internal parts. |
|
|
|
| |
shut off at air outlet. |
|
|
|
|
| |
|
|
|
|
|
|
|
D21245 | 16 — ENG |