Craftsman 919.672240, D25083 owner manual Pump, Wand, Clean and Replace Spark Plug

Models: 919.672240 D25083

1 46
Download 46 pages 28.92 Kb
Page 17
Image 17
Clean and Replace Spark Plug

Clean and Replace Spark Plug

Change the spark plug every 100 hours of operation or once each year, whichever comes first. This will help your engine to start easier and run better.

.030” (0.76 MM)

Wire Gauge

Resistor

PUMP

This screen filter should be checked periodically and cleaned if necessary.

1.Remove filter by grasping end and removing it from water inlet of pump as shown.

2.Clean filter by flushing it with water on both sides.

3.Install filter into water inlet of pump

Filter Screen

WAND

If the nozzle becomes clogged with foreign materials, such as dirt, exces- sive pressure may develop. If the nozzle becomes partially clogged or restricted, the pump pressure will pul- sate. Clean the nozzle immediately using the nozzle kit supplied and the following instructions:

1.Shut off the pressure washer and turn off the water supply.

2.Disconnect spark plug wire.

3.Pull trigger on gun handle to relieve any water pressure.

4.Disconnect the wand from the gun.

5.Remove the nozzle from the end of the wand with the 2mm allen wrench provided as shown.

6.Clean the nozzle using the nozzle cleaner provided or a straight- ened paper clip. Insert into the nozzle end and work back and forth until obstruction is re- moved.

7.Direct water supply into nozzle end to backflush loosened parti- cles for 30 seconds.

8.Reconnect spark plug wire.

9.Reassemble the nozzle to the wand. Tighten securely to pre- vent leaks.

10.Reconnect wand to gun and turn on water supply.

11.Start pressure washer and place wand into high pressure setting to test.

17- ENG