TABLE 1.6a: CROWN CONCENTRIC 80/125 VENT COMPONENTS
(VENT OPTIONS 3,8)
|
|
| USED ON |
| |
CROWN PN | DESCRIPTION | SIZE | VENT | COMMENTS | |
|
|
| OPTION # |
| |
230527 | 90 DEGREE EL (STANDARD) | 80/125mm | 3,8 |
| |
|
|
|
|
| |
230528 | 90 DEGREE EL (SWEEP) | 80/125mm | 3,8 |
| |
|
|
|
|
| |
230526 | 45 DEGREE EL | 80/125mm | 3,8 |
| |
|
|
|
|
| |
230517 | 19 1/2” STRAIGHT | 80/125mm | 3,8 | CAN BE CUT | |
|
|
|
|
| |
230515 | 39” STRAIGHT | 80/125mm | 3,8 | CAN BE CUT | |
|
|
|
|
| |
230518 | 39” STRAIGHT | 80/125mm | 3,8 | MAY NOT BE CUT | |
|
|
|
|
| |
230519 | 78” STRAIGHT | 80/125mm | 3,8 | MAY NOT BE CUT | |
|
|
|
|
| |
230525 | TELESCOPING STRAIGHT | 80/125mm | 3,8 | ADJUSTABLE FROM | |
|
|
|
|
| |
230531 | HORIZONTAL TERMINAL | 80/125mm | 3 |
| |
|
|
|
|
| |
230532 | VERTICAL TERMINAL | 80/125mm | 8 | (NOTE #1) | |
|
|
|
|
| |
230533 | FLAT ROOF FLASHING | 80/125mm | 8 |
| |
|
|
|
|
| |
230535 | SLOPED ROOF FLASHING | 80/125mm | 8 | (NOTE #2) | |
|
|
|
|
| |
230530 | SUPPORT ELBOW WITH | 80/125mm | 8 | (NOTE #3) | |
CHIMNEY CHASE BRACKET | |||||
|
|
|
| ||
|
|
|
|
| |
230536 | SUPPORT BAND | 80/125mm | 3,8 |
| |
|
|
|
|
|
Table 1.6a Notes:
1)Vertical terminal can be used with either of the roof flashings listed beneath it.
2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.
3)Used at base of vertical run inside unused masonry chimney.
TABLE 1.6b: CROWN CONCENTRIC100/150 VENT COMPONENTS
(VENT OPTIONS 8,9)
|
|
| USED ON |
| |
CROWN PN | DESCRIPTION | SIZE | VENT | COMMENTS | |
|
|
| OPTION # |
| |
|
|
|
|
| |
230567 | 90 DEGREE EL (SWEEP) | 100/150mm | 4,9 |
| |
|
|
|
|
| |
230565 | 45 DEGREE EL | 100/150mm | 4,9 |
| |
|
|
|
|
| |
230560 | 19 1/2” STRAIGHT | 100/150mm | 4,9 | CAN BE CUT | |
|
|
|
|
| |
230562 | 39” STRAIGHT | 100/150mm | 4,9 | CAN BE CUT | |
|
|
|
|
| |
230561 | 39” STRAIGHT | 100/150mm | 4,9 | MAY NOT BE CUT | |
|
|
|
|
| |
230563 | 78” STRAIGHT | 100/150mm | 4,9 | MAY NOT BE CUT | |
|
|
|
|
| |
230564 | TELESCOPING STRAIGHT | 100/150mm | 4,9 | ADJUSTABLE FROM | |
|
|
|
|
| |
230569 | HORIZONTAL TERMINAL | 100/150mm | 4 |
| |
|
|
|
|
| |
230570 | VERTICAL TERMINAL | 100/150mm | 9 | (NOTE #1) | |
|
|
|
|
| |
230571 | FLAT ROOF FLASHING | 100/150mm | 9 |
| |
|
|
|
|
| |
230572 | SLOPED ROOF FLASHING | 100/150mm | 9 | (NOTE #2) | |
|
|
|
|
| |
230568 | SUPPORT ELBOW WITH | 100/150mm | 9 | (NOTE #3) | |
CHIMNEY CHASE BRACKET | |||||
|
|
|
| ||
|
|
|
|
| |
230573 | SUPPORT BAND | 100/150mm | 4,9 |
| |
|
|
|
|
|
Table 1.6b Notes:
1)Vertical terminal can be used with either of the roof flashings listed beneath it.
2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.
3)Used at base of vertical run inside unused masonry chimney.
8