3.At this point:

31

Mount the Speaker

2.Plug the Ethernet cable into the Speaker Assembly. Section 2.2.3, "Confirm that the Speaker is Operational and Linked to the Network" explains how the Link and Status LEDs work.

3.At this point:

For drop ceiling mounting, position the VoIP SPEAKER ASSEMBLY in the ceiling so that its screw holes align with those you prepared.

For drywall mounting, place the three PLASTIC RIBBED ANCHORS in the holes you prepared, and position the VoIP SPEAKER ASSEMBLY over them, aligning the screw holes in the assembly with the anchors.

4.To fasten the speaker:

For drop ceiling mounting, use the three 8-32 x 1 1/4" MOUNTING SCREWS, #8 NYLON THUMB NUTS, and #8 FENDER WASHERS to secure the speaker.

Note For weak ceiling tile, CyberData offers a reinforcing mount (CyberData part number 010991A).

For drywall mounting, use the three #8 SHEET METAL SCREWS to secure the speaker.