CYRAQ™ 21

CyberResearch® Displays

2.4 Flush Panel-Mounting: CPxF/CPxR 21A

Prior to performing subsequent steps, ensure the panel-mounting location (including panel thickness) is suitable for the CYRAQ 21, and meets Environmental requirements in Specifications section.

3NOTE: Panel thickness should not exceed: .55" (14.1mm) Suggested panel thickness

is calculated based on standard CYRAQ 21 parts and dimensions, custom units may not meet these specifications. Porongasket is installed by CyberResearch, Inc. on CPBF & CPBR 21 models.

2.4.1Panel Mounting the Monitor

1.Panel cutout is 405mm H x 489mm W for landscape installation (Figure 7).

2.Install the display in panel cut out. Ensure all studs clear cutout opening and Porongasket on the rear of the unit is flush against panel (critical for NEMA compliance).

3NOTE: Steps 3 & 4 require a second person

3.Align studs on the rear of display with the holes in mounting plate from the rear of panel (as seen in Figure 7).

Important!

Do not exceed 30 in/lbs when tightening mounting nuts.

4.Also from rear of the panel, second person must install and tighten the fourteen 10-32 mounting nuts.

See Next Page For Illustration

18

©Copyright 2005 CyberResearch, Inc