CY7C1510JV18, CY7C1525JV18
CY7C1512JV18, CY7C1514JV18
Identification Register Definitions
Instruction Field |
| Value |
| Description | ||
CY7C1510JV18 | CY7C1525JV18 | CY7C1512JV18 | CY7C1514JV18 | |||
|
| |||||
Revision Number | 001 | 001 | 001 | 001 | Version number. | |
(31:29) |
|
|
|
|
| |
Cypress Device ID | 11010011010000100 | 11010011010001100 | 11010011010010100 | 11010011010100100 | Defines the type of | |
(28:12) |
|
|
|
| SRAM. | |
Cypress JEDEC ID | 00000110100 | 00000110100 | 00000110100 | 00000110100 | Allows unique | |
(11:1) |
|
|
|
| identification of | |
|
|
|
|
| SRAM vendor. | |
ID Register | 1 | 1 | 1 | 1 | Indicates the | |
Presence (0) |
|
|
|
| presence of an ID | |
|
|
|
|
| register. |
Scan Register Sizes
Register Name | Bit Size |
Instruction | 3 |
|
|
Bypass | 1 |
|
|
ID | 32 |
|
|
Boundary Scan | 109 |
|
|
Instruction Codes
Instruction | Code | Description |
EXTEST | 000 | Captures the input and output ring contents. |
|
|
|
IDCODE | 001 | Loads the ID register with the vendor ID code and places the register between TDI and TDO. |
|
| This operation does not affect SRAM operation. |
SAMPLE Z | 010 | Captures the input and output contents. Places the boundary scan register between TDI and |
|
| TDO. Forces all SRAM output drivers to a |
RESERVED | 011 | Do Not Use: This instruction is reserved for future use. |
|
|
|
SAMPLE/PRELOAD | 100 | Captures the input and output contents. Places the boundary scan register between TDI and |
|
| TDO. Does not affect the SRAM operation. |
RESERVED | 101 | Do Not Use: This instruction is reserved for future use. |
|
|
|
RESERVED | 110 | Do Not Use: This instruction is reserved for future use. |
|
|
|
BYPASS | 111 | Places the bypass register between TDI and TDO. This operation does not affect SRAM |
|
| operation. |
Document #: | Page 17 of 26 |