D-Link DES-1228P inch, 1U Rack-mount size, 440mm x 210mm x 44mm, A factory reset button x, 0~40C

Models: DES-1228P

1 100
Download 100 pages 56.91 Kb
Page 13
Image 13
Class

 

6. Provide the power following the

 

 

classification below

 

 

 

 

 

 

 

 

 

 

 

Class

Usage

 

Minimum power

 

 

 

 

 

 

levels at output of

 

 

 

 

 

 

PSE

 

 

 

0

Default

 

15.4W

 

 

 

1

Optional

 

4.0W

 

 

 

2

Optional

 

7.0W

 

 

 

3

Optional

 

15.4W

 

 

 

4

Reserved

 

15.4W

 

 

7. DES-1228P follow the PSE pinout standard

 

 

of Alternative A which is sending out power

 

 

over number 1,2,3,6 pins of 8 wires of CAT5

 

 

UTP cable

 

 

 

 

 

 

 

 

 

 

 

Chassis

 

 

 

 

 

 

 

 

 

Dimensions

19-inch, 1U Rack-mount size

 

440mm x 210mm x 44mm

 

 

 

 

 

 

 

 

 

 

Reset button on the

A factory reset button x 1

 

 

front panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Physical & Environment

 

 

 

 

 

 

 

 

AC input

100~240 VAC, 50/60Hz

 

 

 

Internal universal power supply

 

 

 

 

 

 

 

 

Operation

0~40°C

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storage Temperature

-10~70°C

 

 

 

 

 

 

 

 

 

 

 

9