Installation Instructions
Connecting Conduit to the Range
NOTE: See page 14 for instructions to connect an appliance cord to the range.
1.Remove the range electrical access cover from the back of the range.
2.If using a
3.Remove the nut from the conduit strain relief (not included).
4.Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.
5.Before connecting the wires, slide the strain relief nut over the wires and thread it onto the conduit strain relief inside the box. Tighten into place.
6.Connect the white wire to the neutral terminal in the box.
7.Connect the black wire to the L1 power supply terminal.
8.Connect the red wire to the L2 power supply terminal.
9.If using a
Bare wire
connections
Loop and spade terminal
connections
10. Replace the range electrical access cover.
L1 terminal
Neutral terminal
Jumper link
L2 terminal
Back wire
White wire
Red wire
Conduit strain relief nut
3-Wire Conduit Connection -
Where Local Codes Permit
L1 terminal
Neutral terminal
L2 terminal
Link removed Grounding screw
Red wire
Green wire
White wire
Back wire
Conduit strain relief nut
4-Wire Conduit Connection
11