I. REVIEW ¤APLAY (See Fig. 5-10)

 

S/W PULSE TEST PIN

PATH ADJ. FIXTURE

TEST POINTS

 

 

ENVELOPE TEST PIN

PATH ADJ. FIXTURE

 

 

 

 

MEASURING EQUIPMENT

OSCILLOSCOPE

 

 

 

 

ADJUSTMENT

VR CONTROL

PATH ADJ. FIXTURE

 

 

S/T GUIDE ROLLER

TAPE TRANSPORTIN SYSTEM

 

 

 

 

a. Connect the PATH ADJ. FIXTURE to PT01 of the MAIN CIRCUIT BOARD. b. Play back the ALIGNMENT TAPE (SP, COLOR BAR SIGNAL).

c. Connect the channel-1 scope probe to the S/W PULSE TEST PIN of the PATH ADJ. FIXTURE. d. Connect the channel-2 scope probe to the ENVELOPE TEST PIN of the PATH ADJ. FIXTURE.

e. Adjust the VR CONTROL of the PATH ADJ. FIXTURE to the center to obtain the maximum envelope signal of the ALIGNMENT TAPE.

f. After operating the VCR in the REVIEW MODE about 15 secs, change the REVIEW MODE to the

PLAY BACK MODE.

g. Change operation mode from REVIEW MODE to PLAY MODE and then make sure that the envelope waveform is restored to the maximum condition within 3 seconds.

h. If the requirement is not satisfied, make sure that the TAPE runs normal at the lower part of the T GUIDE POST. Then adjust the S/T GUIDE ROLLER precisely.

WAVEFORM

PICTURE

Fig. 5-10 CHECK OF TRANSITIONAL OPERATION (FROM REVIEW WAVEFORM TO PLAY WAVEFORM)

34

Page 35
Image 35
Daewoo K3050MECHA service manual Review ¤APLAY See Fig