Dakota Alert AD-01 Kit Auto Dialer owner manual Don’t position in direct sunlight

Models: AD-01 AD-01 Kit Auto Dialer

1 16
Download 16 pages 12.66 Kb
Page 3
Image 3
Don’t position in direct sunlight.

IMPORTANT

Before you install the PIR Detectors, please take these points into consideration: Don’t position the detectors facing windows.

Don’t position in direct sunlight.

Don’t position above heat sources or in areas of moisture.

Don’t let pets roam into the detection area when the system is armed. The PIR Sensor is set to Alarm 2 so take this into account

when you are programming your voice messages.

Opening the PIR Sensor to access dipswitches and battery connector:

1.Slide the PIR Sensor off the bracket (use the bracket as a template for mounting.)

2.Using a small standard screwdriver, press the release clip on the bottom of the PIR Sensor.

3.Separate the two parts.

Opening the RF Keyfob (only necessary when it is time to change the battery):

1.Using a small Phillips screwdriver, remove the screw from the back of the keyfob.

2.Take a small standard screwdriver and place in groove seperating the two keyfob halves.

3.Slowly twist and the keyfob housing should separate.

3

AD-01 Kit Manual.indd 3

10/15/2009 10:17:55 AM

Page 3
Image 3
Dakota Alert AD-01 Kit Auto Dialer owner manual Don’t position in direct sunlight