Dakota Alert AD-01 Kit Auto Dialer owner manual Entry Delay

Models: AD-01 AD-01 Kit Auto Dialer

1 16
Download 16 pages 12.66 Kb
Page 9
Image 9
Entry Delay:

How to set Entry/Exit Delay times (default both delay set at 30 seconds):

The entry/exit times are the times the Auto Dialer gives you to enter/exit the area covered by the system before it arms/alarms. These are pre-set to 30 seconds. You can also change the timing to instant or 60 seconds.

Entry Delay:

1.Key in the four digit user password code (factory default 1234.)

2.Press PROGRAM > 4 > ENTER

3.Press N (N = 0 for instant; 3 for 30 seconds; 6 for 60 seconds). Press ENTER. Quick guide: Press 1 2 3 4 > PROGRAM > 4 > ENTER > N > ENTER

Exit Delay:

1.Key in the four digit user password code (factory default 1234.)

2.Press PROGRAM > 5 > ENTER

3.Press N (N = 0 for instant; 3 for 30 seconds; 6 for 60 seconds; 9 for 90 seconds). Press ENTER. Quick guide: Press 1 2 3 4 > PROGRAM > 5 > ENTER > N > ENTER

How to set an Entry/Exit delay sound (factory setting Entry/Exit delay with sound):

1.Key in the four digit user password code (factory default 1234.)

2.Press PROGRAM > 7 > ENTER

3.Press N (N = 0 without sound; 1 with sound). Press ENTER.

Quick guide: Press 1 2 3 4 > PROGRAM > 7 > ENTER > N > ENTER

9

AD-01 Kit Manual.indd 9

10/15/2009 10:17:55 AM

Page 9
Image 9
Dakota Alert AD-01 Kit Auto Dialer owner manual Entry Delay