Danby DAC6006DE Limited Air Conditioner Warranty, Table des matières, Identification des pièces

Models: DAC8006DE DAC12060DE DAC6006DE DAC7006DE DAC12666DE DAC10066DE

1 12
Download 12 pages 20.97 Kb
Page 12
Image 12
LIMITED AIR CONDITIONER WARRANTY

LIMITED AIR CONDITIONER WARRANTY

This quality product is warranted to be free from manufacturer’s defects in material and workmanship, provided that the unit is used under the normal operating conditions intended by the manufacturer.

This warranty is available only to the person to whom the unit was originally sold by Danby or by an authorized distributor of Danby, and is non-transferable.

 

TERMS OF WARRANTY

First Year

During the first year (1), any electrical parts of this product found to be defective, including any sealed system units, will be repaired or

 

replaced, at warrantor’s option, at no charge to the ORIGINAL purchaser.

Second Through

During the next four years (4) any part of the sealed system found to be defective (consisting of compressor, condenser, evaporator,

Fifth Year

dryer and all related tubing) will be replaced without charge. The purchaser shall pay for all labor and return freight during this period for

 

repair or replacement of any sealed system components. Any unit being diagnosed as non-functional due to sealed system failure and

 

warranting an exchange will be subject to an appropriate depreciation or user fee, including any and all freight charges being levied

 

against the consumer.

To obtain

Contact your dealer from whom your unit was purchased, or contact your nearest authorized Danby service depot, where service

Service

must be performed by a qualified service technician. If service is performed on the units by anyone other than an authorized service

 

depot, or the unit is used for commercial application, all obligations of Danby under this warranty shall be at an end. It will be the

 

consumer’s responsibility to transport the appliance (at their own expense) to the original retailer (point of purchase) or a service depot

 

for repair.

EXCLUSIONS

Save as herein provided, Danby Products Limited (Canada) or Danby Products Inc. (U.S.A.), there are no other warranties, conditions, representations or guarantees, express or implied, made or intended by Danby Products Limited or its authorized distributors and all other warranties, conditions, representations or guarantees, including any warranties, conditions, representations or guarantees under any Sale of Goods Act or like legislation or statue is hereby expressly excluded. Save as herein provided, Danby Products Limited (Canada) or Danby Products Inc. (U.S.A), shall not be responsible for any damages to persons or property, including the unit itself, howsoever caused or any consequential damages arising from the malfunction of the unit and by the purchase of the unit, the purchaser does hereby agree to indemnify and save harmless Danby Products Limited from any claim for damages to persons or property caused by the unit.

GENERAL PROVISIONS

No warranty or insurance herein contained or set out shall apply when damage or repair is caused by any of the following:

1)Power Failure.

2)Damage in transit or when moving the appliance.

3)Improper power supply such as low voltage, defective house wiring or inadequate fuses.

4)Accident, alteration, abuse or misuse of the appliance such as inadequate air circulation in the room or abnormal operating conditions, (extremely high or low room temperature).

5)Use for commercial or industrial purposes.

6)Fire, water damage, theft, war, riot, hostility, acts of God such as hurricanes, floods etc.

7)Service calls resulting in customer education.

Proof of purchase date will be required for warranty claims; so, please retain bills of sale. In the event warranty service is required, present this document to our

AUTHORIZED SERVICE DEPOT.

 

Warranty Service

 

In Home

 

 

Danby Products Limited

Danby Products Inc.

PO Box 1778, 5070 Whitelaw RD, Guelph, Ontario, Canada N1H 6Z9

PO Box 669, 101 Bentley Court, Findlay, Ohio, U.S.A. 45840

Telephone: (519) 837-0920 FAX: (519) 837-0449

Telephone: (419) 425-8627 FAX: (419) 425-8629

 

02/06

 

11

Table des matières

Page

Fiche signalétique . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Spécifications électriques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Quincaillerie d’installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Installation dans la fenêtre . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17 Instructions de fonctionnement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 Caractéristiques de télécommande . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 Précautions et maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 Guide de dépannage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 Garantie . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22

Identification des pièces

Commutateur pour ventilation d'air frais

 

 

 

 

 

 

 

 

 

Caisson

 

Sortie d'air

 

 

 

 

 

 

 

Intérieure

 

 

 

 

 

 

 

 

 

 

 

 

 

Entrée d'air

Entrée d'air

 

 

 

 

 

Extérieure

 

 

 

 

 

 

 

Intérieure

 

 

 

 

 

 

 

Tableau de

 

 

 

 

 

Filtre à

 

Commande

 

 

 

 

Air

 

Fiche signalétique

DAC

6006DE

7006DE

8006DE

10066DE

12060DE

12666DE

 

 

Voltage

 

115

115

115

115

115

115

Capacité de refroidissement (Btu/h)

6000

7000

8000

10000

12000

12000

Puissance d'entrée

 

560

740

740

920

1110

1110

Régime nominal d'efficacité

 

 

 

 

 

 

énergétique (EER)

 

10.7

10.8

10.8

10.8

10.8

10.8

Ventilateur/vitesse de refroidissement

3/3

3/3

3/3

3/3

3/3

3/3

CFM (pi 3/m3)

 

200/18.6

250/23.2

300/27.9

450/41.8

500/46.5

500/46.5

Niveau du bruit (dB)

 

53

53

53

59

59

59

Dimensions de l’appareil

(po/cm)

 

 

 

 

 

 

 

Largeur

18-1/2 /47

18-1/2 /47

18-1/2 /47

18-7/8 /47.9

18-7/8 /47.9

18-7/8 /47.9

 

Profondeur

16-2/8 /41.3

16-2/8 /41.3

16-2/8 /41.3

22-5/8 /57.5

22-5/8 /57.5

22-5/8 /57.5

 

Hauteur

12-5/8 /32.1

12-5/8 /32.1

12-5/8 /32.1

14-3/8 /36.5

14-3/8 /36.5

14-3/8 /36.5

Window Kit Dimensions (po/cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Largeur maximum

 

34-1/2

/87.6

 

34-1/2

/87.6

 

34-1/2

/87.6

 

40 / 101.6

 

40 / 101.6

 

40 / 101.6

 

Largeur minimum

 

21-1/2

/ 54.6

 

21-1/2

/ 54.6

 

21-1/2

/ 54.6

 

28 / 71.1

 

28 / 71.1

 

28 / 71.1

 

Hauteur minimum

 

3

 

3

 

3

 

2 8

2 8

2 8

 

 

 

13- /8 /34

13- /8 /34

13- /8 /34

15- / /38.7

15- / /38.7

15- / /38.7

Remarque : Les spécifications peuvent être changées sans avis, à titre d'amélioration.