MSI/Plessey
MSI/Plessey — continued
Length Control
Fixed Length Decoding— When fixed length decoding is enabled, the scanner will decode a bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding— When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maxi- mum length.
Configuring Fixed Length Decoding:
1.Scan the START/END bar code.
2.Scan the Fixed Length Decoding bar code.
3.Scan the START/END bar code.
4.Set Length 1 to the first fixed length by following the MSI/Plessey Length 1, Length 2 Pro-
gramming Instructions below.
5.Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the MSI/Plessey Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1.Scan the START/END bar code.
2.Scan the Variable Length Decoding bar code.
3.Scan the START/END bar code.
4.Set Length 1 to the first variable length by following the MSI/Plessey Length 1, Length 2
below.
5. Set Length 2 to the second variable length by following the MSI/Plessey Length 1, Length 2 below.