Datalogic Scanning 1400I Global Prefix/Suffix, Scan the END bar code to exit Programming Mode

Models: 1400I

1 180
Download 180 pages 24.46 Kb
Page 66
Image 66
Magellan® 1400i

Data Editing

Enter prefixes and suffixes in the order in which you want them to appear on the output.

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated in Figure 4-2.

Figure 4-2. Prefix and Suffix Positions

OR...

Prefix

Label ID

AIM ID

Bar Code Data

Label ID

Suffix

00 - 20 Characters (ASCII)

AND

OR

Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies.

1.Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.

2.Scan the START bar code.

3.Scan the SET PREFIX bar code.

4.Reference the ASCII Chart on the inside back cover of this manual, to find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from Appendix C, Alpha-

Numeric Pad.

5. Scan the END bar code to exit Programming Mode.

If less than the expected string of 20 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode.

NOTE

6.The resulting message string would appear as follows:

Scanned bar code data:12345

Resulting message string output: $12345

4-2

Page 66
Image 66
Datalogic Scanning 1400I manual Global Prefix/Suffix, Scan the END bar code to exit Programming Mode