2.4 ELECTRICAL CONNECTIONS AND SETUP

The following figure shows the typical layout. The dotted line in the figure refers to an optional hardware configuration.

PC

Scanner

Auxiliary

Interface

SCANNER

System Cables

Figure 2.5 – System layout

A PC can be quickly connected to the C-BOX 200 (and consequently to the scanner auxiliary interface) through the internal 9-pin connector. This allows monitoring of the data transmitted by the scanner or configuration through the WinHost utility (see the scanner Installation Manual for more details). The scanner auxiliary interface signals are also available on the internal spring clamp connectors.

After making system cabling and switch settings (see sub-paragraphs under 2.4), connect the scanner to the 25-pin connector on the left side of the C- BOX 200 housing.

Switch ON the C-BOX 200 power switch (see Figure 2.6).

After power on, an automatic connection procedure takes place between the C-BOX 200 and the scanner. During this phase, requiring a few seconds, the warning LED is turned ON. Once the procedure had been completed successfully, the warning LED is turned OFF.

After system functioning has been verified, close the C-BOX 200 using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing.