DATALOGIC C-BOX 200
Installation - 17
2.7.1 GET/SEND Buttons
The C-BOX 200 has two internal function buttons (GET, SEND). The
procedure to enable the GET/SEND function is the following:
1. Press both the buttons GET and SEND at the same time for at least one
second; the warning LED is turned ON.
2. Release the buttons.
GET SEND
3. Press the left button corresponding to the GET function or press the
right button corresponding to the SEND function.
GET (left button): the C-BOX 200 reads the current scanner
configuration and permanently copies it in its own memory
support (EEPROM). The C-BOX 200 preserves this
configuration also when switched off.
SEND - (right button): the C-BOX 200 sends the configuration previously
stored in its own permanent memory support to the scanner’s
EEPROM.
NOTE
Once the buttons are released in step 1, a ten-second timeout
starts. If no button is pressed within this time, the procedure will
be cancelled.
In any case, the warning LED is turned OFF at the end of each
procedure.