DATALOGIC

C-BOX 200

2.7.1 GET/SEND Buttons

The C-BOX 200 has two internal function buttons (GET, SEND). The procedure to enable the GET/SEND function is the following:

1.Press both the buttons GET and SEND at the same time for at least one second; the warning LED is turned ON.

2.Release the buttons.

GET SEND

3.Press the left button corresponding to the GET function or press the right button corresponding to the SEND function.

GET – (left button): the C-BOX 200 reads the current scanner configuration and permanently copies it in its own memory support (EEPROM). The C-BOX 200 preserves this configuration also when switched off.

SEND - (right button): the C-BOX 200 sends the configuration previously stored in its own permanent memory support to the scanner’s

EEPROM.

NOTE

Once the buttons are released in step 1, a ten-second timeout starts. If no button is pressed within this time, the procedure will be cancelled.

In any case, the warning LED is turned OFF at the end of each procedure.

Installation - 17

Page 26
Image 26
Datalogic Scanning C-BOX 200 installation manual 1 GET/SEND Buttons, GET Send