Error | Problem | Operation | Reset |
Code | |||
| Internal Booster Tank Thermistor Error | Normal | After replacing failed component, |
| (open) | (internal | alarm resets. |
H4 |
| booster tank |
|
| Thermistor senses abnormal temperature | heaters off) |
|
| (at (heater off) or below |
|
|
H5 | ROM/RAM Error | Unit stops | After replacing control board, alarm |
Control board ROM/RAM fails. |
| resets. | |
|
|
| |
| EEPROM Error | Unit stops | After replacing control board, alarm |
H6 | EEPROM fails. |
| resets. |
|
|
| |
| Phase Reversal Error | Unit stops | After correcting the connection by |
H7 |
|
| swapping two of three wires at the |
Power supply phase is reversed. |
| power switch (GFCI) connection, | |
|
| ||
|
|
| alarm resets. |
2. Error Code Log
Use the "ON/OFF" button to turn off the unit. Press and hold the "MODE" button, then press the "ON/OFF" button. "01" should appear on the display. Use the down arrow button to scroll to service menu items 21 through 25 (Auxiliary Code
Press the "STANDBY/CLEANING" button to exit the service menu. The display goes blank.
To erase the log, press and hold the up and down buttons for 3 seconds with one of the error codes displayed. The unit beeps once and the entire log clears.
29