21

Total Operation Cycles Before

10 to 990 cycles

1 to 99

2

 

Alert

 

 

(20 cycles)

22

Display Hold Function

ON: stays on

on or oF

oF

 

 

OFF: goes off after 10 minutes

 

 

23

Power Supply Lock Function

ON: "Ch" keeps flashing until

on or oF

oF

 

 

electrode is turned off

 

 

 

 

OFF: "Ch" goes off when "ON/

 

 

 

 

OFF" button is switched off

 

 

24

N/A

 

 

 

25

N/A

 

 

 

26

Error Log

NA

Most Recent

NA

through

 

 

Errors

 

30

Note: To erase the log, press

 

26 is most

 

 

and hold the up and down

 

recent.

 

 

buttons for 3 seconds with one

 

"--" is displayed

 

 

of the error codes displayed.

 

if the log is

 

 

The unit beeps once and the

 

empty.

 

 

entire log clears.

 

 

 

8. Temperature Display

Indicates the average water temperature read by the wash tank or internal booster tank thermistor. Indicates wash tank water temperature in wash cycle, rinse (internal booster tank) water temperature in rinse cycle. Press the down button to indicate rinse (internal booster tank) water temperature instead of wash tank water temperature while the dishwasher is in "READY" mode. To change the normal temperature display to the rinse (internal booster tank) water temperature, see "Water Temperature Display" (service menu item 12) in "II. D.7.b) Service Menu Chart."

The temperature display range is 32°F to 199°F (0°C to 99°C). To change the display scale, see "Temperature Display Scale" (service menu item 13) in "II.D.7.b) Service Menu Chart."

The temperature display updates every 30 seconds for the wash tank and every 5 seconds for the internal booster tank.