5)Close the door. “SC” and the “AUTO FILL” lamp start flashing, and the self-cleaning cycle begins. The buzzer sounds and the operation panel turns off when the cycle ends. Move the power switch (GFCI) to the “OFF” position. Turn off the water heater, and the gas and water supplies.

6)Open the door, and remove the upper and lower rinse spray arms. Go on to step 8) of “V.A. Daily Maintenance.”

C.Weekly Maintenance

1. Heater

WARNING

To prevent burns, wait for 10 minutes after draining the unit to clean the interior.

Remove any scraps from the heater, and

 

use a soft brush to wash off residue.

 

2. Exterior

Heater

 

Soft Brush

Do not use a metal brush which may damage the surface.

1)Wipe the exterior with a soft cloth.

2)Use a damp cloth containing a neutral cleaner to wipe off dirt. Then wipe away the residue with a clean cloth.

3. Wash Compartment

1) Tilt back the rack rail, and lift it off the notch.

2) Remove any scraps from the wash tank.

D. Monthly Inspection

1. Power Switch (Ground Fault Circuit Interrupter)

1)Open the cover at the front, and move the power switch (GFCI) to the “ON” position.

2)Press the test switch. The power switch (GFCI) should switch from “ON” to “OFF”.

3)If not, move the power switch (GFCI) to the “OFF” position, and contact an authorized Hoshizaki service company.

2. Water Supply Line

Check the water supply line for damage, deformation, or water leak marks (stains). If any of these conditions are found, contact an authorized Hoshizaki service company.

ON

OFF Test Switch

Water Heater

Damage, deformation or water leaks

66

Page 71
Image 71
Hoshizaki JWE-620UA-6B service manual Weekly Maintenance, Monthly Inspection