I. Specifications
A. Specification Sheet
|
|
| WASH TANK SIDE |
| BOOSTER TANK SIDE | |
AC SUPPLY VOLTAGE | 3 phase |
|
|
| ||
POWER SUPPLY CAPACITY | 15.8kVA(39.7A) |
|
|
| ||
AMPERAGE |
| Max Running 36.6A, Rated Motor 4.2A |
|
|
| |
STARTING AMPERAGE | 26.0A |
|
|
| ||
ELECTRICAL CONSUMPTION | Rated Motor 1.40kW (Power Factor 85%) |
|
|
| ||
|
|
| Max 14.30kW |
|
|
|
HEATER |
| 6.9kW |
| 6.0kW | ||
RACK SIZE |
|
|
|
| ||
NUMBER OF LARGE DISHES / RACK | 16 plates (9.1” DIA) |
|
|
| ||
CYCLE TIME |
| 53 sec (wash 41 sec, dwell 5 sec, rinse 6 sec, dwell 1 sec) | ||||
WATER CONSUMPTION | 0.53Gal/cycle(2.0L/cycle) |
|
|
| ||
OUTSIDE DIMENSIONS | W25.2" × D25.8" × H60.5" (W640 × D655 × H1,537mm) | |||||
EXTERIOR |
| Stainless Steel |
|
|
| |
DOOR |
| Vertical Sliding Door (opening height 18.0") (457mm) | ||||
WASH SYSTEM | Upper and Lower Triple Spray Arms (common arms on top and bottom) | |||||
RINSE SYSTEM | Upper and Lower Wide Angle Spray Arms |
|
|
| ||
PUMP |
| Wash 1HP, Rinse 0.134HP |
|
|
| |
DRAIN SYSTEM | Draw Out Overflow Pipe, Overflow Drain |
|
|
| ||
START |
| Door Switch (start switch mode also available) | ||||
DRY SYSTEM | Residual Heat Drying |
|
|
| ||
REFUSE DISPOSAL | Filter Collection |
|
|
| ||
DETERGENT |
| Not Provided |
|
|
| |
DISPLAY |
| Ready, Auto Fill, Rinse, | ||||
|
|
| Wash Water Temperature, Rinse Water Temperature, Error | |||
TANK CAPACITY | 14.3Gal (54L) |
| 1.9Gal (7.3L) | |||
HOT WATER SUPPLY | Automatic Hot Water Supply by |
| ||||
| Automatic Hot Water Supply by | |||||
|
|
| Microprocessor Control |
| ||
TEMPERATURE CONTROL |
| Water Valve | ||||
Wash: 150ºF(66ºC) min. |
| |||||
| Rinse: 180ºF(82ºC) min. | |||||
|
|
| Thermistor Control: 163ºF(73ºF) - |
| ||
CONNECTION – WATER SUPPLY | 168(76ºF) |
| Thermistor Control: | |||
|
|
| ||||
|
| – DRAIN | Inlet: 3/4"FPT |
|
|
|
|
|
| Outlet: |
|
|
|
|
| WASH TIME | Standard: 1 - 99 sec, in 1 sec steps |
|
|
|
CONTROL |
|
| Long: 10 - 990 sec, in 10 sec steps | Microprocessor control | ||
| RINSE TIME | 5 - 12 sec, Adjustable, in 1 sec steps |
|
|
| |
|
|
|
|
| ||
|
| END BUZZER VOLUME | 0 - Max, Adjustable |
|
|
|
ELECTRIC CIRCUIT PROTECTION | Ground Fault Circuit Interrupter (with Overcurrent Protector) | |||||
BOIL – DRY PROTECTION | Water Level Switch, |
| Float Switch, |
| ||
|
|
| Bimetal Thermostat (Manual - Reset), |
| Bimetal Thermostat (Manual - Reset), |
|
SAFETY SYSTEM | Thermistor (Auto - Reset) |
| Thermistor (Auto - Reset) |
| ||
Door Switch, Emergency Stop by Microprocessor Control | ||||||
WEIGHT |
| Net 247lb (112kg) / Gross 344lb (156kg) |
|
|
| |
PACKAGE |
| Carton + Crate |
|
|
| |
| W32.1"×D34.6"×H68.0" (815mm × 880mm × 1,726mm) | |||||
|
|
| ||||
CERTIFICATION | NSF |
|
|
| ||
|
|
| Universal rack | |||
ACCESSORIES | Installation manual x 1, Maintenance sheet (English and Spanish)x 1 | |||||
|
|
| Inlet water strainer & Packing x 1, |
|
|
|
|
|
| Ambient Temperature: 41 - 95ºF (5ºC - 35ºC) | |||
|
|
| Voltage Range: Rated Voltage ±10% |
|
|
|
OPERATION CONDITIONS | Recommends Water Hardness : 4gpg (grains per gallon) (68.5ppm) or less | |||||
|
|
| Water Supply Temperature: 110 - 167ºF (43ºC - 75ºC) ( Recommends 140 ºF (60ºC)) | |||
|
|
| Water Supply Pressure (Gauge Static Pressure): 10 - 70PSIG (0.07 - 0.48 MPa) |
*The rated properties are based on measurements at ambient temperature of 86ºF (30ºC) according to the Technical Requirements for Electrical Appliances.
*We reserve the right to make changes in specifications and design without prior to notice.
1